BACK
Product Guide
Driling
Driling (solid-carbide)
Micro-MGS
MICRO-MGS
Special Application Notes
For safety and success, high pressure coolant is required.
(Minimum coolant pressure=1000PSI)
Coolant filter must be less than 5 microns.
Fine filtration is necessary to prevent blockage of the coolant holes.
A pilot hole or guide bushing is required.
HOW TO USE
Pilot hole drilling.
(Mitsubishi's MZE, MZS, MWE or MWS is recommended.)
Drill is inserted into the pilot hole.
(Drill is not rotating.)
Coolant is turned ON, raise cutting speed and feed to the recommended cutting condition.
Return to "Pos 2" after drilling end, coolant turned OFF and drill rotation is stopped.
TOP
BACK